Help
RealRead
64 ANSI/ASHRAE/IESNA Standard 90.1-2007 Retail Area 4 = the floor area used for the sale of jewelry, crystal, and china. Exception: Other merchandise categories may be included in Retail Areas 2 through 4 above, provided that justification documenting the need for additional lighting power based on visual inspection, contrast, or other critical display is approved by the authority having jurisdiction. 9.7 Submittals (Not Used) 9.8 Product Information (Not Used) 10. OTHER EQUIPMENT 10.1 General 10.1.1 Scope. This section applies only to the equipment described below. 10.1.1.1 New Buildings. Other equipment installed in new buildings shall comply with the requirements of this section. 10.1.1.2 Additions to Existing Buildings. Other equipment installed in additions to existing buildings shall comply with the requirements of this section. 10.1.1.3 Alterations to Existing Buildings 10.1.1.3.1 Alterations to other building service equipment or systems shall comply with the requirements of this section applicable to those specific portions of the building and its systems that are being altered. 10.1.1.3.2 Any new equipment subject to the requirements of this section that is installed in conjunction with the alterations, as a direct replacement of existing equipment or control devices, shall comply with the specific requirements applicable to that equipment or control devices. Exception: Compliance shall not be required for the relocation or reuse of existing equipment. 10.2 Compliance Path(s) 10.2.1 Compliance with Section 10 shall be achieved by meeting all requirements of Section 10.1, General; Section 10.4, Mandatory Provisions; and Section 10.8, Product Information. 10.2.2 Projects using the Energy Cost Budget Method (Section 11 of this standard) must comply with Section 10.4, the mandatory provisions of this section, as a portion of that compliance path. 10.3 Simplified/Small Building Option (Not Used) 10.4 Mandatory Provisions 10.4.1 Electric Motors. Electric motors shall comply with the requirements of the Energy Policy Act of 1992 where applicable, as shown in Table 10.8. Motors that are not included in the scope of the Energy Policy Act of 1992 have no performance requirements in this section. Common Space Typesa LPD, W/ft2 Building-Specific Space Types LPD, W/ft2 Workshop 1.9 Religious Buildings Sales Area [for accent lighting, see Section 9.6.2(b)] 1.7 Worship Pulpit, Choir 2.4 Fellowship Hall 0.9 Retail Sales Area [for accent lighting, see Section 9.6.3(c)] 1.7 Mall Concourse 1.7 Sports Arena Ring Sports Area 2.7 Court Sports Area 2.3 Indoor Playing Field Area 1.4 Warehouse Fine Material Storage 1.4 Medium/Bulky Material Storage 0.9 Parking Garage?arage Area 0.2 Transportation Airport?oncourse 0.6 Air/Train/Bus?aggage Area 1.0 Terminal?icket Counter 1.5 a In cases where both a common space type and a building-specific type are listed, the building specific space type shall apply. TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method (continued)